GRAMLOCK is a lead-free fiber cement board designed specifically for X-ray radiation shielding. The board is manufactured from gypsum (Dihydrate Gypsum: CaSO₄·2H₂O) reinforced with non-woven glass fiber, providing high structural strength, fire resistance, and effective radiation shielding.
Radiation protection performance is achieved through the incorporation of Barium Sulfate (BaSO₄), allowing the board to deliver shielding efficiency equivalent to lead (Pb), while remaining safe for human health and environmentally friendly.
Technical Specifications
The GRAMLOCK board is available in various thicknesses to meet different radiation shielding requirements.
- Board size: 1.20 m x 2.40 m
Equivalent lead protection:
- 14 mm thickness: Equivalent to 1.0 mm Pb
- 28 mm thickness (double layer of 14 mm): Equivalent to 2.0 mm Pb
All shielding performance has been tested and certified by the Department of Medical Sciences, Ministry of Public Health, Thailand.
Key Features
- Provides X-ray radiation shielding equivalent to conventional lead sheets
- Lead-free material, safer for users and the environment
- Fire resistant and provides thermal insulation
- Tested for X-ray attenuation equivalent to 1.0 mm Pb at 120 kVp
- Strong, durable, and moisture resistant
- Manufactured under ISO 9001 and JIS Q9001 quality standards
- Product origin: Japan
Recommended Applications
Recommended shielding board configuration according to room type:
- Dental X-ray room / Mammography room: 1 layer
- General X-ray room: 2 layers
- Hybrid Operating Room: 2 layers
- CT Scan room: 3 layers
- Angiography / Fluoroscopy / Cardiac Catheterization Lab: 3 layers
The number of layers should be determined based on equipment specifications and radiation safety requirements.
Installation Guidelines
The boards can be cut to size using a circular saw.
All joints, seams, and penetrations must be sealed with X-ray shielding putty to prevent radiation leakage.
For finishing works, a primer sealer may be applied prior to painting or decorative wall finishing to ensure a smooth and durable surface.
2.1. ใช้เลื่อยวงเดือนไฟฟ้าในการตัดแผ่น
2.2. ใช้ PUTTY กันรังสีเอกซเรย์ในบริเวณรอยต่อ
สามารถใช้ Primer sealer ในการปิดรอยและทาสีหรือติด Wall paper เพื่อเก็บงาน
Installation Configurations
The shielding system can be installed in various configurations depending on the required level of radiation protection:
3.1 Single-side shielding equivalent to 1.0 mm
3.2 Single-side shielding equivalent to 2.0 mm
3.3 Single-side shielding equivalent to 3.0 mm
3.4 Double-side shielding equivalent to 1.0 mm
3.5 Double-side shielding equivalent to 2.0 mm
3.6 Double-side shielding equivalent to 3.0 mm
Reference Projects |
|
The GRAMLOCK radiation shielding wall system has been installed in numerous medical facilities, including hospitals, clinics, and specialized medical centers throughout Thailand. |
|
| No | หน่วยงาน |
| 1 | คลินิกหมอสุธีร์ |
| 2 | โรงพยาบาลเทพธารินทร์ |
| 3 | โรงพยาบาลตำรวจ |
| 4 | ศูนย์การแพทย์ฉะเชิงเทรา |
| 5 | โรงพยาบาลลาดพร้าว |
| 6 | โรงพยาบาลจินเวล |
| 7 | โรงพยาบาลกล้วยน้ำ |
| 8 | โรงพยาบาลเกษมราษฎร์ |
| 9 | โรงเรียนนักอัลตราซาวด์ทางการแพทย์ วิทยาลัยการแพทย์เจ้าฟ้าจุฬาภรณ์ |
| 10 | โรงพยาบาลจุฬาภรณ์ |
| 11 | โรงพยาบาลกล้วยน้ำไทย |
| 12 | โรงพยาบาลขอนแก่น |
| 13 | โรงพยาบาลธรรมศาสตร์ |
| 14 | โรงพยาบาลราชวิถี |
| 15 | โรงพยาบาล.มะเร็งลพบุรี |
| 16 | โรงพยาบาลเกษมราชปราจีนบุรี |
| 17 | โรงพยาบาล.สระบุรี |
| 18 | โรงพยาบาล.นครปฐม |
| 19 | โรงพยาบาล สายไหม |
| 20 | เทียนฟ้าประชาการุณย์ ศูนย์ไตเทียมโดยโรงพยาบาลเทียนฟ้ามูลนิธิ |
Technical Note
For radiation shielding applications, the standard board size is 1.20 m x 2.40 m.
For shielding requirements equivalent to 2.0 mm Pb or higher, boards should be installed in multiple layers with proper overlap to ensure continuous radiation protection.
| ความหนา | ขนาดแผ่น กว้าง x สูง | Lead Equivalent (หนาเทียบเท่าแผ่นตะกั่ว) | น้ำหนักต่อ ตรม. |
| 14 มม. | 1220 x 2440 มม. | 1 mmPb | 24 กก. |